Torlon 4503
Torlon 4203
Torlon 4203L
Torlon 4501
Torlon 4301
Torlon 4301
Torlon 5530
Torlon 5030
 
 
 
Units
ASTM Test Method
Compression Molded Polyamideimide
Extruded Polyamideimide
Injection Molded Polyamideimide
Compression Molded Bearing Polyamideimide
Extruded Bearing Grade Poly-amideimide
Injection Molded Bearing Polyamideimide
Compression Molded 30% GF Polyamideimide
Injection Molded 30% GF Polyamideimide
MECHANICAL
1
Strength to Weight Ratio
ksi
-
 
 
 
 
 
 
 
 
2
Specific Gravity @73 F
-
D792
1.40
1.41
1.41
1.45
1.45
1.45
1.61
1.60
3
Tensile Strength @73 F, (ult)/(yld)
psi
D638
18000 (ult)
18000 (ult)
22000 (ult)
10000 (ult)
12000 (ult)
19000
14000 (ult)
24000 (ult)
4
Tensile Modulus of Elasticity @ 73 F
psi
D638
500000
600000
600000
440000
900000
760000
500000
1200000
5
Tensile Elongation at Break @ 73 F
%
D638
5
5
15
3
3
7
3
4
6
Flexural Strength @ 73 F
psi
D790
24000
24000
28000
20000
31000
25000
20000
36000
7
Flexural Modulus of Elasticity @ 73 F
psi
D790
600000
600000
700000
650000
1000000
750000
800000
1000000
8
Shear Strength @ 73 F
psi
D732
-
16000
15000
-
16400
13000
-
24500
9
Compressive Strength, (% Deformation) @73 F
psi
D695
17000 (10)
28000 (10)
32000 (10)
18000 (10)
24000 (10)
24000 (10)
18000 (10)
38000 (10)
10
Compressive Modulus of Elasticity @73 F
psi
D695
350000
700000
700000
350000
950000
950000
350000
600000
11
Hardness, Rockwell, Scale as noted @73 F
-
D785
M119 (E80)
M120 (E80)
M120 (E80)
M106 (E70)
M106 (E70)
M106 (E70)
M120 E77)
M125 (E77)
12
Hardness, Durometer, Shore D @73 F
-
D2240
D90
-
-
D90
-
-
D90
-
13
Izod Impact, (Notched) @73 F
ft-lb/in of notch
D256 TypeA
1.5
2.0
2.5
0.5
0.8
1.1
0.7
1.3
14
Coefficient of Friction, (Dry vs. Steel) Dynamic
-
-
0.30
0.27
0.35
0.20
0.20
0.20
0.20
0.19
15
Limiting PV, (with 4 to 1 factor of safety applied)
psi-ft/min
-
-
17500
-
22500
22500
30000
20000
-
THERMAL
16
Coefficient of Linear Thermal Expansion @73 F
in/in/F
E-831 (TMA)
1.5E-05
1.7E-05
1.7E-05
2.0E-05
1.4E-05
1.4E-05
2.5E-05
1.0E-05
17
Heat Deflection Temperature @ 264 psi
F
D648
532
532
532
534
534
534
520
539
18
Tg-Glass transition temperature, (Amorphous)
F
D3418
527
527
527
527
527
527
527
527
19
Melting Point, (VS=Vicat Softening Temp.)
F
D3418
-
-
-
-
-
-
-
-
20
Continuous Service Temperature in Air, (Max.)
F
-
500
500
500
500
500
500
500
500
21
Thermal Conductivity
BTU-in/hr-ft2-F
-
1.80
1.80
1.80
3.70
3.70
3.70
2.50
2.50
ELECTRICAL
22
Dielectric Strength, Short Term
Volts/mil
D149
580
580
580
-
-
-
700
840
23
Volume Resistivity
ohm-cm
D257
2.0E+17
2.0E+17
2.0E+17
8.0E+15
3.0E+15
8.0E+15
2.0E+17
2.0E+17
24
Dielectric Constant @ 10E6 Hz
-
D150
3.9
3.9
3.4
5.4
6.0
5.4
6.3
6.5
25
Dissipation Factor @ 10E6 Hz
-
D150
0.031
0.031
0.031
0.042
0.037
0.042
0.220
0.023
26
Flammability @ 3.1 mm unless noted
-
UL94
V-O
V-O
V-0
V-0
V-0
V-0
V-0
V-0
H2O
27
Water Absorbtion, Immersion, 24 Hrs
% by wt.
D570(7)
0.35
0.40
0.33
0.30
0.28
0.28
0.30
0.30
28
Water Absorbtion, Saturation
% by wt.
D570(7)
1.70
1.70
1.70
1.50
1.50
1.50
1.50
1.50

 

 

home / company / why cct? / parts / materials